Quality Benefits
– Captive nut on cover
– Pressure switch pipe connection 1/4″ female NPT
– Adjustment instructions are inside the top cover
– Contact points open on cut-out pressure – switch off
– Points close on cut-in or pressure drop – switch on
– Each turn of the adjustment screw = 2 PSI
Note: Factory set pressure range settings are +/- 8 PSI. A mechanical pressure switch factory set can not be more accurate and field adjustments may be needed. (This is not a defect). The maximum operating pressure of the pump and system the switch is to be used with must be a minimum of 12 PSI above the switch shut offsetting. The use of this switch outside of the noted parameters will not be warranted.
Note: Pressure switches overheated or burned up inside due to rapid cycling will not be warranted.
Certifications & Warnings